pyhoff/tests/test_terminals.py

96 lines
4.1 KiB
Python
Raw Normal View History

import inspect
import pyhoff as pyhoff
import pyhoff.devices as devices
from pyhoff.devices import DigitalInputTerminal, DigitalOutputTerminal, AnalogInputTerminal, AnalogOutputTerminal
def test_terminal_plausib():
2025-02-17 08:31:28 +00:00
"""
Test if all implemented BusTerminal classes in devices
have the plausible parameters
"""
for n, o in inspect.getmembers(devices):
if inspect.isclass(o) and o not in [DigitalInputTerminal,
DigitalOutputTerminal,
AnalogInputTerminal,
AnalogOutputTerminal]:
print('Terminal: ' + n)
if issubclass(o, DigitalInputTerminal):
assert o.parameters.get('input_bit_width', 0) > 0
# assert o.parameters.get('output_bit_width', 0) == 0
assert o.parameters.get('input_word_width', 0) == 0
assert o.parameters.get('output_word_width', 0) == 0
if issubclass(o, DigitalOutputTerminal):
# assert o.parameters.get('input_bit_width', 0) == 0
assert o.parameters.get('output_bit_width', 0) > 0
assert o.parameters.get('input_word_width', 0) == 0
assert o.parameters.get('output_word_width', 0) == 0
if issubclass(o, AnalogInputTerminal):
assert o.parameters.get('input_bit_width', 0) == 0
assert o.parameters.get('output_bit_width', 0) == 0
assert o.parameters.get('input_word_width', 0) > 0
if issubclass(o, AnalogOutputTerminal):
assert o.parameters.get('input_bit_width', 0) == 0
assert o.parameters.get('output_bit_width', 0) == 0
assert o.parameters.get('output_word_width', 0) > 0
2025-02-17 08:31:28 +00:00
def rw_all_bus_terminals(bus_cupler: pyhoff.BusCoupler):
for bt in bus_cupler.bus_terminals:
if isinstance(bt, AnalogOutputTerminal):
for channel in range(1, bt.parameters.get('output_word_width', 0) + 1):
bt.set_normalized(channel, 0)
bt.set_normalized(channel, 1)
bt.set_normalized(channel, 2)
if isinstance(bt, AnalogInputTerminal):
for channel in range(1, bt.parameters.get('input_word_width', 0) + 1):
assert bt.read_channel_word(channel, 1337) == 1337
assert bt.read_channel_word(channel, 1337) == 1337
assert bt.read_channel_word(channel, 1337) == 1337
if isinstance(bt, DigitalOutputTerminal):
for channel in range(1, bt.parameters.get('output_bit_width', 0) + 1):
assert not bt.write_coil(channel, True)
assert not bt.write_coil(channel, False)
if isinstance(bt, DigitalInputTerminal):
for channel in range(1, bt.parameters.get('input_bit_width', 0) + 1):
assert bt.read_input(channel) is None
2025-02-17 08:31:28 +00:00
def test_terminal_setup():
"""
Test if all implemented BusTerminal classes in devices can
be instantiated and connected to a bus coupler
"""
terminal_classes: list[type[pyhoff.BusTerminal]] = []
for n, o in inspect.getmembers(devices):
if inspect.isclass(o) and o not in [DigitalInputTerminal,
DigitalOutputTerminal,
AnalogInputTerminal,
AnalogOutputTerminal]:
if issubclass(o, pyhoff.BusTerminal):
print(n)
terminal_classes.append(o)
# Beckhoff
2025-02-17 08:31:28 +00:00
bus_cupler = devices.BK9050('localhost', 11255, terminal_classes, timeout=0.001)
assert len(terminal_classes) == len(bus_cupler.bus_terminals)
assert bus_cupler.get_error() == 'connection failed', bus_cupler.get_error()
rw_all_bus_terminals(bus_cupler)
# Wago
bus_cupler = devices.WAGO_750_352('localhost', 11255, terminal_classes, timeout=0.001)
assert len(terminal_classes) == len(bus_cupler.bus_terminals)
assert bus_cupler.get_error() == 'connection failed', bus_cupler.get_error()
rw_all_bus_terminals(bus_cupler)